CN
Input devices
Signal type
Voltage range
Reset method
The following 6 products are eligible
NPFSR-K131AMD
Output: 3NO+1NC contrast
The inputs of K series E-STOP, safety gate, safety light curtain input safety relays are normally closed contact signals, which are used for emergency braking or the protection of people entering dangerous areas, and widely used in machining and other industries. Main features: 1oo2 architecture; With detection of shorts across contacts; With auto reset and manual reset function;The safety function remains effective in the case of a component failure;The correct opening and closing of the safety function relays is tested automatically in each on-off cycle.
NPFSR-K131MD
Output: 3NO+1NC contrast
The inputs of K series E-STOP, safety gate input safety relays are normally closed contact signals, which are used for emergency braking or the protection of people entering dangerous areas, and widely used in machining and other industries. Main features: 1oo2 architecture. With detection of shorts across contacts. With monitored manual reset function. The safety function remains effective in the case of a component failure. The correct opening and closing of the safety function relays is tested automatically in each on-off cycle.
NPFSR-K122AMD
Output:2NO+2NC contrast
The inputs of K series E-STOP, safety gate, safety light curtain input safety relays are normally closed contact signals, which are used for emergency braking or the protection of people entering dangerous areas, and widely used in machining and other industries. Main features: 1oo2 architecture. With detection of shorts across contacts. With auto reset and manual reset function. The safety function remains effective in the case of a component failure. The correct opening and closing of the safety function relays is tested automatically in each on-off cycle.
NPFSR-K122MD
Output:2NO+2NC contrast
The inputs of K series E-STOP, safety gate input safety relays are normally closed contact signals, which are used for emergency braking or the protection of people entering dangerous areas, and widely used in machining and other industries. Main features: 1oo2 architecture. With detection of shorts across contacts. With monitored manual reset function. The safety function remains effective in the case of a component failure. The correct opening and closing of the safety function relays is tested automatically in each on-off cycle.
NPFSR-K122YAMD
Output:2NO, non-delay + 2NO, d-delay contrast
The inputs of K series E-STOP, safety gate input safety relays are normally closed contact signals, which are used for emergency braking or the protection of people entering dangerous areas, and widely used in machining and other industries. Main features: 1oo2 architecture. With detection of shorts across contacts. With auto reset and manual reset function. The safety function remains effective in the case of a component failure. The correct opening and closing of the safety function relays is tested automatically in each on-off cycle.
NPFSR-K122YMD
Output:2NO, non-delay + 2NO, d-delay contrast
The inputs of K series E-STOP, safety gate input safety relays are normally closed contact signals, which are used for emergency braking or the protection of people entering dangerous areas, and widely used in machining and other industries. Main features: 1oo2 architecture. With detection of shorts across contacts. With monitored manual reset function. The safety function remains effective in the case of a component failure. The correct opening and closing of the safety function relays is tested automatically in each on-off cycle.